MIL-PRF-28750F
3.13.9 Overload: Will not trip current (short circuit protected SSR's) (when specified, see 3.1). When SSR's are
3.13.10 Overload: Must trip current (short circuit protected SSR's) (when specified, see 3.1). When SSR's are
3.13.11 Turn-on into a shorted load (when specified, see 3.1). When SSR's are tested as specified in 4.7.7.5, the
SSR shall shut OFF.
3.13.12 Shorted load with SSR ON (when specified, see 3.1). When SSR's are tested as specified in 4.7.7.6, the
SSR shall shut OFF.
3.13.13 Status turn-on time (when specified, see 3.1). When SSR's are tested as specified in 4.7.7.7, the status
turn-on time shall not exceed the specified value (see 3.1).
3.13.14 Status "ON" voltage (when specified, see 3.1). When SSR's are tested as specified in 4.7.7.8, the status
"ON" voltage shall be as specified (see 3.1).
3.13.15 Status turn-off time (when specified, see 3.1). When SSR's are tested as specified in 4.7.7.9, the status
turn-off time shall not exceed the specified value.
3.13.16 Status "OFF" voltage (when specified, see 3.1). When SSR's are tested as specified in 4.7.7.10, the
status "OFF" voltage shall be as specified (see 3.1).
3.13.17 Status blocking voltage (when specified, see 3.1). When SSR's are tested as specified in 4.7.7.11, the
status (off) current shall not exceed the specified value.
3.13.18 Status leakage current (when specified, see 3.1). When SSR's are tested as specified in 4.7.7.12, the
status leakage current shall not exceed the specified value.
3.13.19 Turn-on time. When SSR's are tested as specified in 4.7.7.13, the turn-on time shall not exceed the
specified value (see 3.1).
3.13.20 Turn-off time. When SSR's are tested as specified in 4.7.7.14, the turn-off time shall not exceed the
specified value (see 3.1).
3.13.21 Output voltage drop. When SSR's are tested as specified in 4.7.7.15, the output voltage drop shall not
exceed the value specified (see 3.1).
3.13.22 Output leakage current. When SSR's are tested as specified in 4.7.7.16, the leakage current in the output
circuit shall not exceed the specified value (see 3.1).
3.13.23 Transient voltage (when specified, see 3.1). When SSR's are tested as specified in 4.7.7.17, the output
shall not turn on (see 3.1).
3.13.24 DC offset voltage (ac SSR's only) (when specified, see 3.1). When SSR's are tested as specified in
3.13.25 Waveform distortion (ac SSR's only) (when specified, see 3.1). When SSR's are tested as specified in
4.7.7.19, the waveform distortion (commutation spikes) shall not exceed the specified value (see 3.1).
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business