MIL-PRF-28750F
Verify that the SSR shuts OFF within the specified (see 3.1) time by measuring the output current I(output),
d.
or the output voltage V(output).
Verify that the SSR meets the trip characteristics at the various current levels specified (see 3.1).
e.
4.7.7.5 Turn-on into a shorted load (see 3.13.11).
a.
Test setup in accordance with figure 1.
Apply specified (see 3.1) voltage, and frequency (if applicable).
b.
c.
Close switch S1.
Apply specified (see 3.1) input conditions to turn the SSR on.
d.
e.
Verify that the SSR shuts OFF by measuring the output current I(output).
Reset SSR, then repeat twice the steps outlined in 4.7.7.5a through 4.7.7.5e. Repeating this turn-on into a
f.
shorted load test twice can be eliminated if the manufacturer has demonstrated process control under the
SPC program (see 3.3.1), or other method that has been approved by the qualifying activity. If the design,
material, technology, or processing of the part is changed or, if there are any quality problems or failures,
the qualifying activity may require resumption of the specified testing. Deletion of testing does not relieve
the manufacturer from meeting the test requirement in case of dispute.
4.7.7.6 Shorted load with SSR ON (see 3.13.12).
a.
Test setup in accordance with figure 1.
Apply the specified (see 3.1) load, voltage, and frequency (if applicable).
b.
c.
Apply specified (see 3.1) input conditions to turn the SSR on.
d.
Close switch S1.
e.
Verify the SSR shuts OFF by measuring the output current I(output).
Reset SSR, then repeat twice the steps outlined in 4.7.7.6a through 4.7.7.6e. Repeating this shorted load
f.
test twice can be eliminated if the manufacturer has demonstrated process control under the SPC program
(see 3.3.1), or other method that has been approved by the qualifying activity. If the design, material,
technology, or processing of the part is changed or, if there are any quality problems or failures, the
qualifying activity may require resumption of the specified testing. Deletion of testing does not relieve the
manufacturer from meeting the test requirement in case of dispute.
4.7.7.7 Status turn-on time (see 3.13.13).
a.
Test setup in accordance with figure 1.
Apply specified (see 3.1) load, voltage, and frequency (if applicable).
b.