MIL-PRF-28750F
3.13.26 Minimum load current rating (ac SSR's only) (when specified, see 3.1). When SSR's are tested as
specified in 4.7.7.20, the SSR shall remain ON.
3.13.27 Exponential rate of voltage rise (when specified, see 3.1 and 6.11). When SSR's are tested as specified in
3.13.28 Zero crossover (ac SSR's only) (when specified, see 3.1). When SSR's are tested as specified in 4.7.7.22,
the SSR turn-on shall occur within the specified (see 3.1) zero voltage crossover, and SSR turn-off shall occur within
the specified (see 3.1) zero current crossover.
3.13.29 Electrical system spike (when specified, see 3.1). When SSR's are tested as specified in 4.7.7.23, they
shall withstand the voltage specified without damage.
3.13.30 Overload (non-short circuit protected SSR's only) (when specified, see 3.1). When SSR's are tested as
specified in 4.7.7.24, they shall withstand the specified overload without damage.
3.13.31 Power dissipation (when specified, see 3.1). When SSR's are tested as specified in 4.7.7.25 the power
dissipation shall not exceed the specified value (see 3.1).
3.13.32 Electromagnetic interface (when specified, see 3.1). When solid state relays are tested as specified in
3.14 Resistance to solvents. When SSR's are tested as specified in 4.7.8, the marking shall remain legible.
3.15 Shock (specified pulse). When SSR's are tested as specified in 4.7.9, there shall be no evidence of physical
or mechanical damage.
3.16 Vibration. When SSR's are tested as specified in 4.7.10, there shall be no evidence of physical or mechanical
damage.
3.17 Terminal strength. When SSR's are tested as specified in 4.7.11, there shall be no evidence of loosening or
breaking of the terminals; and there shall be no deformation to the threads of screw terminals; no damage to the
insulating base of plug-in SSR's; nor shall there be any other damage which would adversely affect the normal
operation of the SSR. Bending of solder terminals shall not be construed as damage; bending of plug-in terminals
shall not be construed as damage, provided they can be reformed in a manner to permit proper mating with the
applicable sockets.
3.18 Moisture resistance (applicable to nonhermetically sealed SSR's only). When SSR's are tested as specified
in 4.7.12, there shall be no evidence of breaking, cracking, chipping or flaking of the finish, or loosening of the
terminals. After the 24-hour drying period, SSR's shall meet the following requirements:
Insulation resistance: As specified in 3.11.
a.
b.
DWV: As specified in 3.12.
Input turn-off voltage: As specified in 3.13.4.
c.
Input turn-on voltage: As specified in 3.13.3.
d.
e.
Output voltage drop: As specified in 3.13.21.