MIL-PRF-28750F
Verify that the status current I(status) is as specified (see 3.1).
e.
4.7.7.12 Status leakage current (see 3.13.18).
a.
Test setup in accordance with figure 1.
Apply specified (see 3.1) load, voltage, and frequency (if applicable).
b.
c.
Apply specified (see 3.1) input conditions and necessary status turn off conditions.
Apply the maximum specified (see 3.1) status voltage V(status),
d.
Verify that the status leakage current I(status) is as specified (see 3.1).
e.
4.7.7.13 Turn-on time (see 3.13.19).
a.
Test setup in accordance with figure 1.
Apply the specified (see 3.1) load, voltage, and frequency (if applicable).
b.
c.
Apply specified (see 3.1) input turn-on conditions.
Verify that the SSR turns ON in the specified (see 3.1) time by measuring the output voltage V(output).
d.
4.7.7.14 Turn-off time (see 3.13.20).
a.
Test setup in accordance with figure 1.
Apply the specified (see 3.1) load, voltage, and frequency (if applicable).
b.
c.
Apply specified (see 3.1) input turn-on conditions, then apply the specified (see 3.1) input turn-off
conditions.
Verify that the SSR turns OFF in the specified (see 3.1) time by measuring the output voltage V(output).
d.
4.7.7.15 Output voltage drop (see 3.13.21).
Test setup in accordance with figure 1.
a.
Apply the specified (see 3.1) load, voltage, and frequency (if applicable).
b.
c.
Apply specified (see 3.1) input turn-on conditions.
Verify that the voltage drop is as specified (see 3.1) by measuring V(output).
d.
4.7.7.16 Output leakage current (see 3.13.22).
a.
Test setup in accordance with figure 1.
Apply the specified (see 3.1) load, voltage, and frequency (if applicable).
b.
27