MIL-R-83726/7E
Recycle characteristics:
Before time out: Power must be removed for 50 milliseconds or 5 percent of the nominal time delay, whichever is greater, to insure a loss in timing no greater than 10 percent.
After time out: Power must be applied for 90 milliseconds or 1 percent of the nominal time delay, whichever is greater, after which an interruption of 10 milliseconds will insure a loss in timing no greater than 10 percent.
Polarity protection: The unit will be inoperative during, and undamaged by, reversal of the input polarity.
ELECTRICAL DATA:
Insulation resistance at 500 V dc 1/: Initial: 1,000 megohms minimum. After life or at high temperature: 500 megohms minimum. Dielectric withstanding voltage: |
||
Sea level |
Altitude |
|
(V rms, 60 Hz) |
(V rms 60 Hz) |
|
Between case and all contacts |
1,000 |
|
Between case and inputs 1 and 9 1/ |
500 |
350 2/ |
Between all contacts and inputs 1 and 9 |
1,000 |
|
Between open contacts in the energized and |
||
unenergized positions |
500 |
|
Between contact poles |
1,000 |
Transients in accordance with MIL-STD-704 for 28 V dc system (figure 11). ENVIRONMENTAL DATA:
Temperature range: -65°C to +125°C. Altitude: 80,000 feet.
Shock: 50 G's for 11 ±1 milliseconds, MIL-STD-202, method 213, condition A.
Contact opening: 10 microseconds maximum duration. Monitor in accordance with method 310 of
Vibration (sinusoidal): 10-80 Hz at .06 inch peak double amplitude, 80-3,000 Hz at 20 G's. Acceleration: 50 G's steady state, no opening of closed contacts.
Sealing: Not applicable.
1/ Input terminals X1 and X2 must be connected together during this test.
2/ All pins to case for this test.
4