MIL-R-83726/7E
REQUIREMENTS: CONTACT DATA:
Configuration: 2PDT; 2 form C.
Life/load rating (relay case grounded):
Type of load |
Life (cycles) |
28 V dc |
Amperes 115 V ac - 1 phase 60 and 400 Hz |
Resistive Inductive Lamp |
100,000 100,000 100,000 |
2.0 .75 0.1 |
0.3 0.3 0.1 |
Contact voltage drop:
Initial: 0.150 volt maximum.
After life tests: 0.200 volt maximum.
Intermediate current: Applicable in accordance with MIL-R-5757.
Contact bounce: 2 milliseconds maximum, to be measured on each contact set using an oscilloscope, contacts shall be loaded with rated current and voltage.
Overload:
Resistive: 200 percent rated current. Inductive: 200 percent rated current.
INPUT DATA:
Duty power: Continuous.
Range of voltage: 18 to 31 V dc.
Minimum voltage - high temperature: 18 V dc.
Maximum current at 25°C and 28 V dc: 80 milliamperes. Time delay: Fixed time 0.06 to 300 seconds (see table I).
Time delay tolerance: ±10 percent except as noted in table I, under all combinations of input voltage and all environmental conditions.