MIL-R-83516B
6.8.2 Contacts. The current-carrying parts of a relay that open or close electrical circuits.
6.8.3 Contact, dry reed. A glass enclosed magnetically-operated contact using reeds as the contacting members.
6.8.4 Contact arrangement. The combination of contact forms that make up the entire relay switching structure.
6.8.5 Operate time. The interval between the application of a step function input signal and closing of all normally open contacts. Bounce time is included.
6.8.6 Pickup voltage. The voltage at which the armature seats against the coil core by assuming its fully operated position.
6.8.7 Relay. Most simply defined as an electrically controlled device that opens and closes electrical contacts to effect the operation of other devices in the same or another electrical circuit.
6.8.8 Release time. The interval between the trailing edge of a step function input signal and closing of all normally closed contacts. Bounce time is included.
6.9 Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes
no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to
the last previous issue.
Custodian: Preparing activity: Air Force - 85 DLA - CC
DLA - CC
Review activity: Air Force - 99
(Project 5945-2011-062)
NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https://assist.daps.dla.mil/.
18
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business