MIL-R-835168
4.5.1.1 Inspection lot. An inspection lot, as far as practicable, shall consist of all relays covered by a single specification sheet produced under essentially the same conditions within a period not to exceed 4 weeks and offered for inspection at one time.
TA8LE II. Qualification inspection. 1/
Inspection 2/ |
Requirement paragraph |
Test method paragraph |
Number of sample relays to be inspected |
Number of defectives permitted |
Group I Visual and mechanical examination (internal) - - - - - - - - - - |
3.1, 3.3, 3.4, and 3.31 |
4.6.1.1 |
1 open sample unit |
1 |
Visual and mechanical examination (external) - - - - - - - - - Thermal shock - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Run in - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Contact stability - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Solderability (applicable to relays with solder terminals) - - - Dielectric withstanding voltage - - - - - - - - - - - - - - - - - - - - - Insulation resistance - - - - - - - - - - - - - - - - - - - - - - - - - - - - DC coil resistance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Coil transient suppression (applicable to relays with internal diodes) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Pickup and dropout voltages (as applicable, see 3.1) - - - - - Coil power dissipation (when specified, see 3.1) - - - - - - - - Static contact resistance - - - - - - - - - - - - - - - - - - - - - - - - - Operate and release times (as applicable, see 3.1) - - - - - - |
3.1, 3.3, 3.4, 3.30 and 3.31 3.5 3.6 3.7 3.8 3.9 3.10 3.11 3.12 3.13 3.14 3.15 3.16 |
4.6.1.2 4.6.2 4.6.3 4.6.4 4.6.5 4.6.6 4.6.7 4.6.8 4.6.9 4.6.10 4.6.11 4.6.12 4.6.13 |
All relays in sample 3/ 2 1/ All relays in sample 3/ |
|
Group II Resistance to solvents - - - - - - - - - - - - - - - - - - - - - - - - - - Contact noise (when specified, see 3.1) - - - - - - - - - - - - - - Thermal EMF (when specified, see 3.1) - - - - - - - - - - - - - - Capacitance (when specified, see 3.1) - - - - - - - - - - - - - - - Shock (specified pulse)- - - - - - - - - - - - - - - - - - - - - - - - - - Vibration, high frequency - - - - - - - - - - - - - - - - - - - - - - - - Moisture resistance - - - - - - - - - - - - - - - - - - - - - - - - - - - - Visual and mechanical examination (external)- - - - - - - - - - Group III Contact sticking - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Resistance to soldering heat - - - - - - - - - - - - - - - - - - - - - - Salt spray (corrosion) - - - - - - - - - - - - - - - - - - - - - - - - - - - Lead integrity - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - DC coil resistance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Static contact resistance - - - - - - - - - - - - - - - - - - - - - - - - - Pickup and dropout voltage (as applicable, see 3.1)- - - - - - Operate and release times (as applicable, see 3.1) - - - - - - Dielectric withstanding voltage - - - - - - - - - - - - - - - - - - - - - Insulation resistance - - - - - - - - - - - - - - - - - - - - - - - - - - - - Group IV Cross talk (applicable to relays with electrostatic shielding) Life - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - DC coil resistance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Static contact resistance - - - - - - - - - - - - - - - - - - - - - - - - - Pickup and dropout voltage (as applicable, see 3.1)- - - - - - Operate and release times (as applicable, see 3.1) - - - - - - Dielectric withstanding voltage - - - - - - - - - - - - - - - - - - - - - Insulation resistance - - - - - - - - - - - - - - - - - - - - - - - - - - - - |
3.17 3.18 3.19 3.20 3.21 3.22 3.23 3.1, 3.3, 3.4, 3.30 and 3.31 3.24 3.25 3.26 3.27 3.11 3.15 3.13 3.16 3.9 3.10 3.28 3.29 3.11 3.15 3.13 3.16 3.9 3.10 |
4.6.14 4.6.15 4.6.16 4.6.17 4.6.18 4.6.19 4.6.20 4.6.1.2 4.6.21 4.6.22 4.6.23 4.6.24 4.6.8 4.6.12 4.6.10 4.6.13 4.6.6 4.6.7 4.6.25 4.6.26 4.6.8 4.6.12 4.6.10 4.6.13 4.6.6 4.6.7 |
4 4 4 |
0 |
See footnotes at top of next page.