MIL-R-39016/40G
LIFE TEST REQUIREMENTS: Intermediate current: 50,000 cycles. Electrical: 100,000 cycles. Mechanical: 1,000,000 cycles.
Part or Identifying Number (PIN): M39016/40 - (plus dash number from table I).
TABLE I. Dash number and characteristics. 1/
Dash number |
Mounting |
Coil voltage V dc |
Coil resist- ance (±10%) (+25°C) ohms |
Over temperature range |
||||||
Terminals |
Speci- fied pickup value voltage (V dc) |
Speci- fied hold value voltage (V dc) |
Speci- fied dropout value (voltage) (V dc) |
|||||||
Solder lug |
Wire lead (SP) 2/ |
Wire lead |
Wire lead (PI) |
Rated 3/ |
Max |
|||||
-001 |
-007 |
-013 |
-019 |
Flange A |
26.5 |
32.0 |
390 |
18.0 |
14.0 |
1.2 |
-002 |
-025 |
-014 |
--- |
Flange B |
||||||
--- |
-008 |
-028 |
-020 |
No mount |
||||||
-003 |
-009 |
-015 |
-021 |
Flange A |
12.0 |
15.0 |
100 |
9.0 |
5.8 |
0.6 |
-004 |
-026 |
-016 |
--- |
Flange B |
||||||
--- |
-010 |
-029 |
-022 |
No mount |
||||||
-005 |
-011 |
-017 |
-023 |
Flange A |
6.0 |
8.0 |
25 |
4.5 |
2.9 |
0.3 |
-006 |
-027 |
-018 |
--- |
Flange B |
||||||
--- |
-012 |
-030 |
-024 |
No mount |
1/ Each relay possesses high level and low level capabilities. However, relays previously tested or used above 10 mA resistive at 6 V dc maximum or peak ac open circuits not recommended for subsequent use in low level applications.
2/ CAUTION: Solder pin relays are not intended for plug-in socket use.
3/ CAUTION: The use of any coil voltage less than the rated voltage will compromise the operation of the relay.
QUALIFICATION INSPECTION:
Qualification inspection and sample size: See table II.
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business