MIL-R-39016/40G
ELECTRICAL DATA:
Insulation resistance: 1,000 megohms minimum, except the resistance between coil and case at high temperature shall be 500 megohms, or greater.
Dielectric withstanding voltage: |
Sea level V rms (60 Hz) |
Altitude V rms (60 Hz) |
|
Between case, frame, or enclosure and all |
|||
contacts in the energized and de-energized |
500 |
||
positions. |
350 |
||
Between case, frame, or enclosure and coils. |
500 |
All terminals |
|
Between all contacts and coils. |
500 |
to case |
|
Between open contacts in the energized and |
de- |
||
energized positions. |
350 |
||
Between contact poles. |
500 |
ENVIRONMENTAL DATA:
Temperature range: -65°C to +125°C.
Vibration (sinusoidal): MIL-STD-202, method 204 (15 g, 10 to 2,000 Hz). Contact chatter shall not exceed
10 microseconds maximum for closed contacts, and 1 microsecond maximum closure for open contacts.
Vibration (random): MIL-STD-202, method 214, test condition IB. Contact chatter shall not exceed 10 microseconds maximum for closed contacts and 1 microsecond maximum closure for open contacts (applicable to qualification and group C testing only).
Shock (specified pulse): MIL-STD-202, method 213, test condition C (100 g). Contact chatter shall not exceed
10 µs maximum for closed contacts, and 1 µs maximum closure for open contacts. Magnetic interference: Applicable.
Resistance to soldering heat: Applicable, except for plug-in relays. Acceleration: 100 g.
PHYSICAL DATA:
Termination: See figure 1 and table I.
Solderability: Applicable, except for plug-in terminals. Terminal strength: Applicable (1.0 ±0.3 pounds pull). Dimensions and configuration: See figure 1.
Weight: 0.35 ounce maximum.
Identification marking (full): Applicable, except marking surface for date code is optional.
5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business