MIL-R-39016/40G
Inches |
mm |
Inches |
mm |
.002 |
0.05 |
.200 |
5.08 |
.003 |
0.08 |
.250 |
6.35 |
.005 |
0.13 |
.300 |
7.62 |
.015 |
0.38 |
.390 |
9.91 |
.020 |
0.51 |
.400 |
10.16 |
.090 |
2.29 |
.500 |
12.70 |
.094 |
2.39 |
.600 |
15.24 |
.100 |
2.54 |
.800 |
20.32 |
.110 |
2.79 |
1.062 |
26.97 |
.120 |
3.05 |
1.078 |
27.38 |
.125 |
3.18 |
1.310 |
33.27 |
.150 |
3.81 |
1.750 |
44.45 |
.187 |
4.75 |
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for general information only.
3. Unless otherwise specified, tolerance is ±.010 (0.25 mm).
4. X1 terminal shall be identified with a contrasting bead. Relays which require coil polarity observance shall have a plus (+) sign placed on the schematic diagram as shown.
5. Shape of lug (solder) terminals is optional.
6. Schematic diagram shall be marked on this surface.
7. Identification marking shall be marked on this surface.
8. Terminal numbers in circuit diagram are for reference only. Numbers shall not appear on relay.
9. Wire lead, plug-in (PI), shall provide the operational, environmental, and interface characteristics to provide a reliable interconnect to gold-plated contacts. Wire leads shall be gold plated. One system for gold plating that may be used is ASTM 8488, type 3, class 1.25 with a nickel underplate of 50 to 150 microinches thick. The gold plating system shall enable the product to meet the performance requirements of this specification and shall be approved by the qualifying activity.
FIGURE 1. Dimensions and configuration - Continued.
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business