MIL-PRF-6106/13F
2
Power spectral density: 0.4 G2/Hz, 50 to 2,000 Hz (0.2 G /Hz) for -006, -009, and -018 only.
Duration: 15 minutes, each plane.
Acceleration: 15 g's. 2/
ELECTRICAL CHARACTERISTICS:
Insulation resistance, initial: 100 megohms.
After life or environmental tests: 50 megohms.
Dielectric withstanding voltage (seal level): 2 to 5 seconds.
After life tests
Initial
Coil to case
1,000 V rms
1,000 V rms
Auxiliary contacts
1,000 V rms
750 V rms
All other points
1,250 V rms
1,000 V rms
Dielectric withstanding voltage (altitude): 1 minute. 3/
80,000 feet
300,000 feet
Coil to case
350 V rms
500 V rms
Auxiliary contacts
350 V rms
500 V rms
All other points
350 V rms
500 V rms
Maximum contact drop, initial: 0.150 volt.
After life test: 0.175 volt.
Overload current: 50 amperes dc, 80 amperes ac.
Rupture current: 60 amperes dc, 100 amperes ac.
RFI specification (applicable to coil circuits of ac operated relays): MIL-STD-461.
Part Number: M6106/13-(dash number from table I).
Qualification by similarity: See MIL-PRF-6106.
____________
3/ Dielectric rating may be improved by suitable insulation of terminals and wiring after installation.