MIL-PRF-39016/53C
REQUIREMENTS:
Contact data:
Load ratings:
High level (relay case grounded):
Resistive: 2 amperes at 28 V dc; 0.125 ampere at 115 V ac, (60 and 400 Hz); 0.5 ampere at 115 V ac,
(60 and 400 Hz) with case not grounded.
Inductive: 0.5 ampere at 200 mH inductive at 28 V dc.
Lamp: 0.10 ampere at 28 V dc.
Low level: 10 µA to 50 µA at 10 mV to 50 mV dc or peak ac.
Intermediate current: Applicable.
Contact resistance and voltage drop:
Initial: 0.050 ohm maximum.
High level:
During life: Not more than 5 percent of open circuit voltage.
After life: 0.150 ohm maximum.
Low level:
During life: 33 ohms maximum.
After life: 0.150 ohm maximum.
Intermediate current:
During intermediate current: 1 ohm maximum.
After intermediate current: 3 ohms maximum.
Contact bounce: 2.0 milliseconds (ms) maximum. (Applicable to failure rate level "L").
Contact stabilization time: 2.5 ms maximum. (Applicable to failure rate levels "M", "P", and "R").
Overload (high level only): 4 amperes resistive at 28 V dc, 1.0 ampere inductive at 28 V dc. (ac not applicable).
Coil data: See table I.
Operate time: 4.0 ms maximum over temperature range with rated coil voltage.
Release time: 6.0 ms maximum over temperature range from rated coil voltage.
3