MIL-PRF-39016/45E
TABLE I. Dash number and characteristics. 1/ 2/
Dash numbers
Coil voltage
At 25°C
Over temperature
(V dc) 4/
range
Specified
Specified
Coil
pickup
pickup
Solder
Printed
Mount
resist-
(latch/reset)
(latch/reset)
lug
wire
Rated
Max
ance
voltage value
voltage value
(PW)
(ohms
(V dc)
(V dc)
.187
±10%)
±.020
Max
Min
Max
Min
001
002
A
5.0
6.7
45
2.7
1.6
3.8
1.0
003
004
B
005
006
C
007
008
A
6.0
8.0
63
3.25
2.0
4.5
1.3
009
010
B
011
012
C
013
014
A
12.0
16.0
254
6.5
4.0
9.0
2.6
015
016
B
017
018
C
019
020
A
26.5
32.0
1,000
13.0
8.0
18.0
5.2
021
022
B
023
024
C
025
026
A
48.0
64.0
3,800
26.0
16.0
36.0
10.4
027
028
B
029
030
C
1/
WARNING: When latching relays are installed in equipment, the latch and reset coils
should not be pulsed simultaneously. Coils should not be pulsed with less than the nominal
coil voltage and the pulse width should be a minimum of three times the specified operate
time of the relay. If these conditions are not followed, it is possible for the relay to be in the
magnetically neutral position.
2/
Each relay possesses high level and low level capabilities. However, relays previously
tested or used above 10 mA resistive at 6 V dc maximum or peak ac open circuits not
recommended for subsequent use in low level applications.
3/
The suffix letter L, M, P, or R to designate the applicable failure rate level shall be added to
the applicable listed dash number. Failure rate level (percent per 10,000 cycles): L, 3.0;
M, 1.0; P, 0.1; R, 0.01. Example: 001L - - - - - - - - - -012R.
4/
CAUTION: The use of any coil voltage less than the rated coil voltage will compromise the
operation of the relay.
QUALIFICATION INSPECTION:
Qualification inspection and sample size: See table II.