MIL-PRF-39016/45E
REQUIREMENTS:
CONTACT DATA:
Load ratings:
High level (relay case grounded), resistive:
Resistive: 2.0 ampere at 28 V dc; 0.150 ampere at 115 V ac, 60 and 400 Hz.
Inductive: 0.75 ampere at 28 V dc with 200 millihenries inductance.
Lamp: 0.160 ampere at 28 V dc.
Low level: 10 to 50 ľA at 10 to 50 mV dc or peak ac.
Intermediate current: Applicable.
Contact resistance or voltage drop:
Initial: 0.050 ohm maximum.
High level:
During life: Not more than 5 percent of open circuit voltage.
After life: 0.100 ohm maximum.
Low level:
During life: 50 ohms maximum.
After life: 0.150 ohm maximum.
Intermediate current:
During intermediate current: 3 ohms maximum.
After intermediate current: 0.100 ohm maximum.
Contact stabilization time: 5 milliseconds (ms) maximum. (Applicable to failure rate levels "M", "P", and "R").
Overload (high level only): Two times rated current.
Neutral screen: Applicable.
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business