MS25468L
REQUIREMENTS:
Dimensions, configuration, and circuit diagram: See figure 1. Dash numbers and general characteristics: See table I. Contact data:
Load ratings: See table II.
Maximum contact drop, initial: 0.150 V.
After life test: 0.175 V.
Overload current: 40 amperes dc; 60 amperes ac. Rupture current: 50 amperes dc; 80 amperes ac.
Coil data: See table III.
Duty rating: continuous. Electrical data:
Minimum insulation resistance:
Initial: 100 megohms. After life or environmental test: |
50 megohms. |
|
Dielectric strength (sea level). |
||
Initial |
After life tests |
|
Coil to case Aux contacts |
1,000 V rms N/A |
1,000 V rms N/A |
All other points |
1,500 V rms |
1,125 V rms |
Dielectric strength (altitude).
(When mounted in mating socket) 80,000 ft |
||
Coil to case Aux contacts All other points |
N/A N/A N/A |
250 V rms 350 V rms |
Group B and Group C inspections may be suspended at the discretion of the qualifying activity.