MIL-R-83726/14D
TABLE I. Dash number and time delay characteristics. 1/
Dash number |
Time delay seconds ±10% |
Dash number |
Time delay seconds ±10% |
Dash number |
Time delay seconds ±10% |
Dash number |
Time delay seconds ±10% |
-1000 -5000 -7500 -1001 -2001 -3001 -4001 -5001 -6001 -7001 -8001 -9001 -1002 |
.100 2/ .500 2/ .750 2/ 1 2 3 4 5 6 7 8 9 10 |
-1202 -1402 -1602 -1802 -2002 -2202 -2502 -3002 -3502 -4002 -4502 -5002 -5502 -6002 |
12 14 16 18 20 22 25 30 35 40 45 50 55 60 |
-6502 -7002 -7502 -8002 -8502 -9002 -9502 -1003 -1103 -1203 -1303 -1403 -1503 -1603 |
65 70 75 80 85 90 95 100 110 120 130 140 150 160 |
-1703 -1803 -1903 -2003 -2103 -2203 -2303 -2403 -2503 -2603 -2703 -2803 -2903 -3003 |
170 180 190 200 210 220 230 240 250 260 270 280 290 300 |
1/ Dash numbers represent commonly used delay times and do not constitute a complete listing of available dash numbers. Additional time delay relays within the .100- to 300- second delay range are available. To establish Part or Identifying Numbers (PIN's) not listed in table I (see "PIN" herein.)
2/ Add ±10 milliseconds to ±10 percent tolerance. Operate time: See table I.
Release time: 25 ms maximum.
Recycle time: 50 ms maximum. Electrical data:
Insulation resistance at 500 V dc: 1/ Initial: 1,000 megohms minimum.
After life or environmental tests: 500 megohms minimum.
Dielectric strength (sea level): Input (X1 - X2) 1/
All other points.
Dielectric strength (altitude) (80,000 feet): 2/ Input (X1 - X2): 350 V rms. 1/
All other points: 350 V rms.
1/ Input terminals X1 and X2 must be connected together during this test.
2/ Dielectric rating may be improved by suitable insulation of terminals and wiring after installation,
500 V rms at 80,000 feet.
4
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business