REQUIREMENTS: Contact data:
Configuration: 4PDT.
Life/load ratings (relay case grounded):
Type of load |
Life (cycles) |
Amperes |
|
28 V dc |
115/200 volts 1 and 3 phase, 400 Hz |
||
Resistive Inductive Motor Lamp Reduced current resistive |
100,000 20,000 100,000 100,000 400,000 |
10 8 4 2 2.5 |
10 8 4 2 2.5 |
Contact voltage drop: Initial: 0.150 volt.
After life tests: 0.175 volt.
Minimum current: Applicable in accordance with MIL-PRF-6106. Contact bounce: 1 ms maximum.
Overload:
DC: 40 amperes. AC: 60 amperes.
Rupture:
DC: 50 amperes. AC: 80 amperes.
Input data:
Duty rating: Continuous.
Maximum voltage (over temperature range): 30 V dc. Nominal voltage (over temperature range): 28 V dc. Minimum voltage (over temperature range): 20 V dc. Minimum voltage high-temperature test: 21 V dc. Minimum voltage continuous current test: 23.5 V dc.
Maximum current at 25°C: 0.150 ampere.