MIL-R-5757J
TABLE I. Qualification inspection.
Inspection |
Requirement paragraph |
Test method paragraph |
Number of sample units to be inspected |
Number of failures allowed |
Q1 Visual and mechanical inspection (internal) 1/ Screening Solderability (3 sample units) 2/ Dielectric withstanding voltage 3/ Insulation resistance 3/ Electrical characteristics 3/ Visual and mechanical inspection (external) (dimensional check on 2 sample units only) Seal |
3.1, 3.27 and 3.28 3.5 3.6 3.9 3.8 3.10 3.1,3.27, and 3.29 3.7 |
4.6.1 4.6.2, 4.6.3 4.6.4 4.6.7 4.6.6 4.6.8 4.6.1 4.6.5 |
All sample units |
0 |
Q2 Thermal shock Resistance to solvents Shock (specified pulse) Vibration (sinusoidal) Vibration (random) Acceleration Terminal strength Dielectric withstanding voltage 3/ Insulation resistance 3/ Electrical characteristics 3/ Seal |
3.11 3.26 3.12 3.13 3.13 3.14 3.15 3.9 3.8 3.10 3.7 |
4.6.9 4.6.24 4.6.10 4.6.11.1 4.6.11.2 4.6.12 4.6.13 4.6.7 4.6.6 4.6.8 4.6.5 |
4 |
1 |
Q3 Magnetic interference (when specified) Coil life Resistance to soldering heat Salt atmosphere (corrosion) Dielectric withstanding voltage 3/ Insulation resistance 3/ Electrical characteristics 3/ Seal |
3.16 3.18 3.19 3.20 3.9 3.8 3.10 3.7 |
4.6.14 4.6.16 4.6.17 4.6.18 4.6.7 4.6.6 4.6.8 4.6.5 |
4 |
1 |
See footnotes at end of table.