MIL-PRF-83726/31J
ELECTRICAL REQUIREMENTS:
Transients: +80 volts in accordance with MIL-STD-704, figure 13.
Spike:
Self-generated: ±50 volts maximum.
Spike transients: ±600V, 10 microseconds maximum.
Susceptibility: + 80 V maximum; -600 V maximum.
RS103) for PIN's with suffix letter W. (EMI test limits will not be exceeded during the timing interval or
when continuously energized under steady-state conditions in accordance with the EMI test of MIL-
Insulation resistance: 1,000 megohms at 500 V dc at sea level, and 100 V dc at 80,000 feet between each pin
and case. (Terminals X1, X2, C1, D1, and D3 must be connected together during this test. Insulation resistance
is measured between all mutually insulated terminals and between all terminals and case.)
Dielelectric withstanding voltage: 1,000 V rms at 60 Hz at sea level, and 350 V rms at 80,000 feet between case
and pins connected together. (Terminals X1, X2, C1, D1, and D3 must be connected together during this test.
Dielectric withstanding voltage is measured between all mutually insulated terminals and between all terminals
and case.)
ENVIRONMENTAL REQUIREMENTS:
Ambient temperature (operating or nonoperating): -55C to +125C.
Vibration (sinusoidal): 30 g's, 10 Hz to 3,000 Hz
2
Vibration (random): 0.4 g /Hz power spectral density, 50 Hz to 2,000 Hz in accordance with
MIL-STD-202, method 214, test condition 1G. Duration of 15 minutes each plane.
Shock (specified pulse): 100 g's, 6 ms ±1 ms, ½ sine, 3 axes.
Acceleration: 15 g's in any axis.
Seal: Hermetic.
Maximum altitude rating: 80,000 feet.
PHYSICAL REQUIREMENTS:
Dimensions and configuration: See figure 1.
Mating socket: M12883/40-01, M12883/40-05, M12883/40-07, M12883/40-11,
M12883/40-13, M12883/40-17, M12883/40-19, or M12883/40-23 specified in MIL-DTL-12883/40.
(CAUTION: Consideration should be given to ambient temperature and current requirements when using wire
barrels size 20.)
Terminations: See figure 1.
Terminal strength: 3 pounds pull.
Weight: 2.5 ounces maximum.
Marking: See MIL-PRF-83726. In addition, relays shall be marked with the ESDS identifier as specified in