TABLE III. Dash numbers and characteristics. 1/
Coil data
Dash number 2/
Mount
At 25C
Over temperature range
Maximum pickup voltage
90
Coil voltage
Specified
Solder
Socket
Continuous
Sol
Coil
Specified
Specified Specified Specified Specified
High
(V dc) 3/
pickup
hook
pin
current
der
resistance
hold
dropout
pickup
hold
dropout
temperature
solder
voltage
test
pin
(ohms)
test
pin
(minimum) (V dc) 4/
(V dc) 4/
(V dc) 4/ (V dc) 4/ (V dc) 4/ (V dc) 4/
Rated
Max
No
001
002
003
---
mount
6
7.3
18
3.3
1.6
0.5
4.5
2.3
0.25
5.0
5.7
004
005
006
---
RVFM
6
7.3
18
3.3
1.6
0.5
4.5
2.3
0.25
5.0
5.7
007
008
---
009
HFM
6
7.3
18
3.3
1.6
0.5
4.5
2.3
0.25
5.0
5.7
No
010
011
012
---
mount
12
14.5
85
6.5
3.3
0.75
9.0
4.5
0.5
9.9
11.25
013
014
015
---
RVFM
12
14.5
85
6.5
3.3
0.75
9.0
4.5
0.5
9.9
11.25
016
017
---
018
HFM
12
14.5
85
6.5
3.3
0.75
9.0
4.5
0.5
9.9
11.25
No
019
020
021
---
mount
28
440
13.5
5.5
2.3
18.0
7.0
1.5
19.8
22.5
022
023
024
---
RVFM
28
440
13.5
5.5
2.3
18.0
7.0
1.5
19.8
22.5
025
026
---
027
HFM
28
440
13.5
5.5
2.3
18.0
7.0
1.5
19.8
22.5
No
028
029
030
---
mount
48
50
1400
24.0
10.0
3.0
36.0
12.0
2.4
40.0
44.0
031
032
033
---
RVFM
48
50
1400
24.0
10.0
3.0
36.0
12.0
2.4
40.0
44.0
034
035
---
036
HFM
48
50
1400
24.0
10.0
3.0
36.0
12.0
2.4
40.0
44.0
1/ Each relay possesses high level and low level capabilities. However, relays previously tested or used above 10 mA resistive at 6 V dc maximum or peak ac open
circuits are not recommended for subsequent use in low level applications.
2/ The suffix letter L, M, P, or R to designate the applicable failure rate level shall be added to the applicable listed dash number. Failure rate level (percent per 10,000
cycles): L, 3.0; M, 1.0; P, 0.1; R, 0.01. Example: 001L, 002R.
3/ CAUTION: The use of any coil voltages less than the rated coil voltage will compromise the operation of the relay.
4/ Pickup, hold, and dropout voltages as shown are for test purposes only and are not to be used for design criteria.
5/ When maximum ambient temperature does not exceed +85C, the maximum coil voltage shall be 32 V dc.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business