MIL-PRF-83536/1B
Bend: Applicable.
Twist: Not applicable.
Socket pin terminals:
Pull force:
For .040 diameter terminals: 5 pounds ±0.5 pound.
For .050 diameter terminals: 10 pounds ±0.5 pound (applicable to polarizing pin only).
Bend: Applicable.
Twist: Not applicable.
Terminal solderability: Applicable to solder pin and solder hook terminals only.
Seal: Hermetic.
Marking: Applicable.
Part or Identifying Number (PIN): M83536/1 (dash number from table III and suffix letter designating failure rate
level).
Qualification inspection:
Qualification inspection and sample size: See table IV.
TABLE IV. Qualification inspection and sample size 1/.
Single submission
Group submission
18 units plus 1 open unit for
M83536/1-024
18 units plus 1 open unit for
level L at C = 0 2/
level L at C = 0 2/
33 units plus 1 open unit for
M83536/1-024
33 units plus 1 open unit for
level M at C = 0 2/
level M at C = 0 2/
Qualification inspection as
M83536/1-024
Qualification inspection as
applicable
applicable
M83536/1-020
2 units, qualification inspection
M83536/1-025
table, Q2, shock, vibration,
M83536/1-027
acceleration, terminal strength,
and seal.
M83536/1-002
2 units, qualification inspection
M83536/1-015
table, Q1.
M83536/1-036
1/ For retention of qualification or extension of qualification to lower failure rate levels, all life test data
accumulated on MIL-PRF-83536/2 may be used in addition to MIL-PRF-83536/1 data. Prior to
performance of retention of qualification testing, the relay manufacturer shall preselect the
sampling plan.
2/ The number of units required for qualification testing shall be increased as required in Q5, table II of
MIL-PRF-83536, if the contractor elects to test the number of units permitting one or more failures.
Prior to performance of qualification testing, the relay manufacturer shall preselect the sampling
plan.
10
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business