MIL-PRF-39016/6L
REQUIREMENTS:
CONTACT DATA:
Load ratings:
Type 1 1/
Type 2 1/
High level (relay case grounded):
Resistive:
2 A at 28 V dc
2 A at 28 V dc
0.3 A at 115 V ac
0.1 A at 115 V ac
(60 and 400 Hz)
(60 and 400 Hz)
Inductive:
0.75 A at 28 V dc
0.5 A at 28 V dc
with 0.200 H inductance
with 0.200 H inductance
Lamp:
0.160 A at 28 V dc
0.160 A at 28 V dc
10 to 50 µA at 10 to
10 to 50 µA at 10 to
Low level:
50 mV dc or peak ac
50 mV dc or peak ac
Intermediate current:
Applicable
Applicable
Contact resistance and voltage drop:
High level:
Before life: 0.050Ω maximum.
During life: Not more than 5 percent of open circuit voltage.
After life: 0.100Ω maximum.
Low level:
Before life: 0.050Ω maximum.
During life: 33Ω maximum.
After life: 0.150Ω maximum.
Intermediate current:
Before: 0.050Ω maximum.
During: 1Ω maximum.
After: 0.100Ω maximum.
Contact bounce: 2.0 ms maximum (applicable to failure rate level L).
Contact stabilization time: 2.5 ms maximum (applicable to failure rate levels M, P, and R).
Overload (high level only): Two times rated current.
COIL DATA: See table I.
Operate time: 4 ms maximum over temperature range with rated coil voltage.
Release time: 4 ms maximum over temperature range from rated coil voltage.