MIL-PRF-39016/48D
LIFE TEST REQUIREMENTS:
High level: 100,000 cycles per relay.
Low level: 100,000 cycles plus 900,000 cycles mechanical life.
Part or Identifying Number (PIN): M39016/48 - (dash number from table I and suffix letter designation failure rate
level).
TABLE I. Dash number and characteristics. 1/
At 20C
Coil voltage 3/
Over temperature range
Dash
V dc
number
Rated
Max
Coil
Specified
Specified
Specified
Specified
Specified
Specified
ohms
hold
dropout
pickup
hold
dropout
pickup
15%
value
value
value
value
value
value
(voltage)
(voltage)
(voltage)
(voltage)
(voltage)
(voltage)
(V dc)
(V dc)
(V dc)
(V dc)
(V dc)
(V dc)
001
5
7
120
2.75
1.7
0.2
4.2
2.6
0.1
002
12
14
720
6.5
3.9
0.6
10.0
5.9
0.3
003
26.5
28
3,100
14.5
8.5
1.0
22.0
13.0
0.5
1/ Each relay possesses high level and low level capabilities. However, relays previously tested or used above 10 mA
resistive at 6 V dc maximum or peak ac open circuit are not recommended for subsequent use in low level
applications.
2/ The suffix letter L, M, P, or R to designate the applicable failure rate level shall be added to the applicable listed
dash number. Failure rate level (percent per 10,000 cycles): L, 3.0; M, 1.0; P, 0.1; R, 0.01.
EXAMPLE, 001L - - - - - - - 003M.
3/ CAUTION: Use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
4/ Allow 10 percent increase in maximum operate voltages after life tests.