MIL-PRF-39016/37D
TABLE II. Qualification inspection and sample size. 1/
Single submission
Group submission
24 units plus 1 open unit for
M39016/37-023 24 units plus 1 open unit for
level L at C = 0 2/
level L at C = 0 2/
33 units plus 1 open unit for
33 units plus 1 open unit for
level M at C = 0 2/
level M at C = 0 2/
Qualification inspection as
Qualification inspection as
applicable.
applicable.
M39016/37-001 2 units, each part number,
M39016/37-006
qualification inspection
M39016/37-010
table, group II.
M39016/37-019
M39016/37-018
2 units, qualification
inspection table, group II
and shock, vibration,
acceleration, terminal
strength, and seal.
1/
For retention of qualification or extension of qualification to lower failure rate levels, all life test data accumulated
on MIL-PRF-39016/38 may be used in addition to MIL-PRF-39016/37 data. Prior to performance of retention of
qualification testing; the relay manufacturer shall preselect the sample size.
2/
The number of units required for qualification testing shall be increased as required in group V, table II,
MIL-PRF-39016, if the relay manufacturer elects to test the number of units permitting one or more failures. Prior
to performance of retention of qualification inspection testing; the relay manufacturer shall preselect the sample
size.
QUALIFICATION INSPECTION (reduced testing): See table III.
If the relays produced for MIL-PRF-39016/37 are similar in construction and design except for the steering diode and
coil to the relays produced for MIL-PRF-39016/38, then reduced testing for qualification of MIL-PRF-39016/37 relays
may be performed concurrent with or subsequent to successful qualification of MIL-PRF-39016/38 relays.
TABLE III. Qualification inspection (reduced testing).
Examination or test
2 units each coil voltage Group II of qualification inspection table.
1 unsealed sample unit Internal examination.
Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where
changes from the previous issue were made. This was done as a convenience only and the Government assumes
no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the
requirements of this document based on the entire content irrespective of the marginal notations and relationship to
the last previous issue.
Referenced documents. In addition to MIL-PRF-39016, this document references the following: