MIL-PRF-39016/37D
TABLE I. Dash number and chacteristics. 1/
Dash number 2/
Coil
Voltage 3/
At 25°C
Over temp range
V dc
Mount
Wire
Solder
Wire
Rated Max
Coil
Speci-
Speci-
Speci-
Speci-
Speci-
Speci-
lead
lug
lead
Resist-
fied
fied
fied
fied
fied
fied
(SP)
ance
pickup
hold
dropout
pickup
hold
dropout
ohms
voltage
voltage
voltage
voltage
voltage
voltage
±10%
(V dc)
V dc)
(V dc)
(V dc)
(V dc)
(V dc)
001
--
002
No
5
7
44
2.4
1.45
0.26
3.3
2.0
0.16
mount
003
--
004
6
8
56
2.7
1.6
0.3
3.8
2.2
0.18
--
005
006
A
007
008
009
B
010
--
011
No
9
12
140
4.4
2.6
0.5
6.0
3.6
0.3
mount
012
--
013
12
16
210
5.4
3.2
0.6
7.4
4.5
0.36
--
014
015
A
016
017
018
B
019
--
020
No
18
24
650
9.5
5.6
1.0
12.8
7.7
0.6
mount
021
--
022
26.5
35
1350
13.5
8.1
1.5
18.0
10.8
0.9
--
023
024
A
025
026
027
B
1/
Each relay possesses high level and low level capabilities. However, relays previously tested or used above 10
mA resistive at 6 V dc maximum or peak ac open circuit are not recommended for subsequent use in low level
applications.
2/
The suffix letter L, M, P, or R to designate the applicable failure rate level shall be added to the applicable listed
dash number. Failure rate (percent per 10,000 cycles): L, 3.0; M, 1.0; P, 0.1; R, 0.01.
Example, 001L --- 027R.
3/
CAUTION: The use of any coil voltage less than the rated coil voltage will compromise the operation of the
relay.
6