MIL-PRF-39016/29G
TABLE I. Dash numbers and characteristics. 1/ 2/
Over
At 25°C
Dash numbers 3/
temperature
Coil
range
Number
voltage
.500
Coil
Speci-
Lead
Speci-
Lead
Lead
Spreader
of
V dc 7/
Min
fied
length
resist-
mounting
fied
length
length
leads
leads
ance
pickup
1.500
pickup
.187
.500
pad
±.010
with
ohms
(latch/
min
(latch/
min
(figure 3)
±10%
ground
reset)
4/
5/
reset)
Rated
Max
6/
value
value
(voltage)
(voltage)
(V dc)
(V dc)
025
037
049
061
9
6.0
8.0
120
3.5
4.5
026
038
050
062
9
9.0
12
280
5.3
6.8
027
039
051
063
9
12
16
500
7.0
9.0
028
040
052
064
9
18
24
1,130
10.5
13.5
029
041
053
065
9
26.5
32
2,000
14.2
18
030
042
054
066
9
5.0
6.0
61
2.8
3.7
031
043
055
067
10
5.0
6.0
61
2.8
3.7
032
044
056
068
10
6.0
8.0
120
3.5
4.5
033
045
057
069
10
9.0
12
280
5.3
6.8
034
046
058
070
10
12
16
500
7.0
9.0
035
047
059
071
10
18
24
1,130
10.5
13.5
036
048
060
072
10
26.5
32
2,000
14.2
18
073
11
12
16
500
7.0
9.0
074
11
5.0
6.0
61
2.8
3.7
075
11
6.0
8.0
120
3.5
4.5
076
11
9.0
12
280
5.3
6.8
077
11
18
24
1,130
10.5
13.5
078
11
26.5
32
2,000
14.2
18
1/ Each relay possesses high level and low level capabilities. However, relays previously tested or used
above 10 mA resistive at 6 V dc maximum or peak ac open circuits not recommended for subsequent use
in low level applications.
2/ WARNING: When latching relays are installed in equipment, the latch and reset coils should not be pulsed
simultaneously. Coils should not be pulsed with less then the nominal coil voltage and the pulse width
should be a minimum of three times the specified operate time of the relay. If these conditions are not
followed, it is possible for the relay to be in the magnetically neutral position.
3/ The suffix letter L, M, P, or R to designate the applicable failure rate level shall be added to the applicable
listed dash number. Failure rate level (percent per 10,000 cycles): L, 3.0; M, 1.0; P, 0.1; R, 0.01.
Example, 025L - - - - - -072R.
4/ 1.500 leads are inactive for new design.
5/ Relays supplied with spreader mounting pads (-061 through -072) shall have the spreader mounting pad
rigidly attached.
6/ Relays are supplied with a case grounding pin welded to the header (see figure 2).
7/ CAUTION: The use of any coil voltage less than the rated coil voltage will compromise the operation of
the relay.
8/ Delete "Coil resistance" and substitute "Coil current" test in all inspection tables of MIL-PRF-39016.
7