TABLE I. Dash numbers and characteristics. 1/ 5/
Dash number 2/
Coil
At 25C
voltage
Over temperature range
Lead
Lead
Lead
Spreader
(V dc) 3/
length
length
length
pads
Coil
Coil circuit
Speci-
Speci-
Speci-
Speci-
Speci-
Speci-
1.500
.187
.500
(fig. 2)
resist-
current
fied
fied
fied
fied
fied
fied
min 4/
±.010
min
ance
7/ (mA)
pickup
hold
drop-
pickup
hold
drop-
(ref.
value
value
out
value
value
out
only)
(volt-
(volt-
value
(volt-
(volt-
value
Ohms
age)
age)
(volt-
age)
age)
(volt-
(V dc)
(V dc)
age)
(V dc)
(V dc)
age)
Rated
Max
Max Min
(V dc)
(V dc)
2.6
0.7
007
019
033
041
5.0
7.0
64
78.1
56.8
2.9
2.2
0.8
3.7
3.0
0.8
008
020
034
042
6.0
10.0
125
48.9
36.3
4.0
2.5
0.9
4.8
4.5
0.9
009
021
035
043
9.0
15.0
400
23.6
18.1
6.1
3.6
1.1
8.0
5.8
1.0
010
022
036
044
12.0
20.0
850
15.0
11.7
7.8
4.6
1.3
11.0
9.0
1.1
011
023
037
045
18.0
30.0
1,600
12.2
9.6
11.3
7.0
1.5
14.5
19.0
13.0
1.3
012
024
038
046
26.5
40.0
3,300
8.8
7.0
15.2
10.8
1.7
27.2
19.0
1.7
029
031
039
047
36.0
57.0
6,500
6.1
4.9
21.7
14.7
2.3
34.8
26.0
2.0
030
032
040
048
48.0
75.0
11,000
4.8
3.9
27.8
19.8
2.8
1/
Each relay possesses high level and low level capabilities. However, relays previously tested or used above 10 mA resistive at 6 V dc maximum
or peak ac open circuit are not recommended for subsequent use in low level applications.
2/
The suffix letter L, M, P, or R to designate the applicable failure rate level shall be added to the applicable listed dash number. Failure rate level
(percent per 10,000 cycles): L, 3.0; M, 1.0; P, 0.1; R, 0.01. Example 013L - - - - - 036R.
3/
CAUTION: The use of any coil voltage less than the rated coil voltage will compromise relay operation.
4/
1.500 leads are inactive for new design.
5/
OTR = over the temperature range, PU = pickup, and DO = dropout.
6/
Relays supplied with spreader pads (-041 through -048) shall have the pad rigidly attached.
7/
Coil resistance not directly measurable at relay terminals. When rated voltage is applied to the coil terminals, the coil circuit current must be
within the limits shown. Measure at 25C at nominal voltage for 5 seconds, maximum.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business