MIL-PRF-39016/21H
ELECTRICAL DATA:
Insulation resistance: 10,000 megohms minimum at 500 V dc, except the resistance between coil and case at high
temperature shall be 1,000 megohms minimum.
Dielectric withstanding voltage:
Post
Sea level
intermediate
Altitude
V rms
current life test
V rms
(60 Hz)
V rms (60 Hz)
(60 Hz)
Between case, frame or enclosure, and all contacts in the
energized and deenergized positions
500
500
Between case, frame or enclosure, and coils
500
500
125
Between all contacts and coil
500
500
All
Between open contacts in the energized and deenergized positions
500
375
terminals
Between contact poles
500
500
to case
Between coils of dual coil relays
N/A
N/A
DIODE CHARACTERISTICS:
Coil transient suppression: Applicable.
Diode block integrity (perform this test after coil transient suppression test in all inspection tables of MIL-PRF-
39016): With applicable voltage applied to the relay coil circuit in the reverse direction, monitor leakage current
with dc microammeter, oscilloscope, or qualifying activity approved test equipment. Leakage current shall not
exceed the specified value.
Block integrity maximum leakage current: 1 A at 50 V dc.
Maximum negative transient: 1.0 volt.
Breakdown voltage: 100 V dc minimum at 10 microamperes (A). (This test may be performed in-process or as
final assembly.)
Semiconductor in-process screening: Applicable, visual inspection of semiconductors shall be in accordance with
MIL-STD-750, methods 2073 or 2074.
ENVIRONMENTAL DATA:
Temperature range: -65C to +125C.
Vibration (sinusoidal): MIL-STD-202, method 204. Contact chatter shall not exceed 10 microseconds maximum for
closed contacts, and 1 microsecond maximum closure for open contacts.
Vibration (random): MIL-STD-202, method 214, test condition IG. Contact chatter shall not exceed 10
microseconds maximum for closed contacts, and 1 microsecond maximum closure for open contacts (applicable to
qualification and group C testing only).
Shock (specified pulse): MIL-STD-202, method 213, test condition B (75 g's). Contact chatter shall not exceed 10
microseconds maximum for closed contacts, and 1 microsecond maximum closure for open contacts.
Magnetic interference: Applicable.