MIL-PRF-39016/21H
REQUIREMENTS:
CONTACT DATA:
Load ratings:
High level (relay case grounded):
Resistive:
1.0 ampere at 28 V dc.
250 milliamperes at 115 V ac 60 and 400 Hz case not grounded.
100 milliamperes at 115 V ac 60 and 400 Hz case grounded.
Inductive load: 0.2 ampere at 28 V dc with 0.32 henry inductance.
Lamp: 0.10 ampere at 28 V dc.
Low level: 10 A to 50 A at 10 mV to 50 mV dc or peak ac.
Intermediate current: Applicable.
Contact resistance or voltage drop:
Initial: 0.100 ohm maximum, 0.125 ohm maximum with spreader pad attached.
High level:
During life: Not more than 5 percent of open circuit voltage.
After life: 0.200 ohm maximum (0.225 ohm maximum with spreader pad attached.)
Low level:
During life: 33 ohms maximum.
After life: 0.150 ohm maximum (0.175 ohm maximum with spreader pad attached.)
Intermediate current:
During life: 1 ohm maximum.
After life: 0.200 ohm maximum (0.225 ohm maximum with spreader pad attached.)
Contact bounce: 1.5 ms maximum (applicable to failure rate level "L").
Contact stabilization time: 2.0 ms maximum (applicable to failure rate levels "M", "P", and "R")..
Overload (high level only): Two times rated current. Not applicable to ac load ratings.
COIL DATA: (See table I).
Operate time: 4.0 ms maximum over temperature range with rated coil voltage.
Release time: 7.5 ms maximum over temperature range.
4