MIL-PRF-39016/14E
Life test requirements:
High level: 100,000 cycles per relay.
Low level: 100,000 cycles plus 900,000 cycles mechanical life.
Part or Identifying Number (PIN): M39016/14-(dash number from table I and suffix letter designating failure rate
level).
TABLE I. Dash numbers and characteristics. 1/
At 25°C
Over temperature range
Mount
Leads
Dash
Coil
Speci-
Speci-
Speci-
Speci-
Speci-
Speci-
Coil
number
voltage
fied
fied
fied
fied
fied
fied
resis-
V dc 3/
2/
pickup
hold
dropout
pickup
hold
dropout
tance
value
value
value
value
value
value
ohms
±10%
(voltage)
(voltage)
(voltage)
(voltage)
(voltage)
(voltage)
Rate
Max
(V dc)
(V dc)
(V dc)
(V dc)
(V dc)
(V dc)
d
004
Flange
Lug
6
7
28
2.7
1.6
0.3
3.8
2.2
0.18
005
No
Wire (SP)
mount
009
Flange
Lug
9
11
73
4.2
2.5
0.4
5.6
3.4
0.25
010
No
Wire (SP)
mount
006
Flange
Lug
12
14
115
5.4
3.2
0.6
7.6
4.3
0.36
007
No
Wire (SP)
mount
011
Flange
Lug
18
22
280
8.4
5.0
0.8
11.2
6.7
0.5
012
No
Wire (SP)
mount
013
Flange
Lug
22
27
430
10.3
6.0
1.0
14.0
8.0
0.6
003
No
Wire (SP)
mount
001
Flange
Lug
008
Flange
Wire (SP)
26.5
35
720
13.5
8.1
1.5
18.0
10.8
0.9
002
No
Wire (SP)
mount
014
Flange
Lug
36
42
1,040
17.1
10.5
1.9
22.8
14.0
1.1
015
No
Wire (SP)
mount
1/
Each relay possesses high level and low level capabilities. However, relays previously tested or used above 10
mA resistive at 6 V dc maximum or peak ac open circuit are not recommended for subsequent use in low level
applications.
2/
The suffix letter L, M, P, or R to designate the applicable failure rate level shall be added to the applicable listed
dash number. Failure rate level (percent per 10,000 operations): L, 3.0; M, 1.0; P, 0.1; R, 0.01. Example,
001L - - - - - 003R.
3/
CAUTION: The use of any coil voltage less than the rated coil voltage will compromise the operation of the
relay.
5