MS24168T
TABLE II. Rated contact load (amperes per pole) case grounded. 1/
Type of load |
Life oper- ating cycles x 103 |
28 V dc |
115 V ac, 1 phase |
115/200 V ac, 3 phase 2/ |
|||||||||
Main |
Aux |
Main |
Aux |
Main |
Aux |
||||||||
NO |
NC |
NO |
NC |
400 Hz |
50/60 Hz |
400 Hz |
50/60 Hz |
400 Hz |
50/60 Hz |
400 Hz |
50/60 Hz |
||
100 |
5 |
5 |
100 |
50 |
5 |
2 |
100 |
50 |
|||||
Resistive |
50 |
100 |
5 |
5 |
50 |
||||||||
Inductive |
10 |
100 |
100 |
20 |
100 |
40 |
|||||||
Motor |
50 |
.75 |
.75 |
.75 |
.75 |
||||||||
Lamp |
50 |
||||||||||||
Transfer load 3/ |
25 |
1.25 |
1.25 |
25 |
12.5 |
1.25 |
1.25 |
25 |
12.5 |
||||
Mechanical life reduced current |
100 |
10 |
4/ |
4/ |
10 |
10 |
10 |
10 |
|||||
Mixed loads |
50 |
1/ Absence of value indicates that parameter is not applicable to this specification sheet.
2/ Absence of value indicates that relay is not rated for three phase applications.
3/ Transfer load indicates relay is suitable for transfer between unsynchronized ac power supplies at the rating indicated.
4/ In accordance with MIL-PRF-6106.
TABLE III. Operating characteristics.
PIN MS24168- |
Coil |
Coil data |
Time (milliseconds maximum) |
||||||||||||||
Rated |
Max |
Max pick-up voltage |
Hold volt- Age 2/ 3/ |
0rop- Out volt- age 2/ 3/ |
Oper- ate 4/ |
Re- Lease 5/ |
Contact bounce 4/ |
||||||||||
Volts 1/ |
Freq. Hz |
Res +15% -10% (Ω) |
Volts |
Coil cur- rent |
Nor- mal 2/ |
High temp test |
Cont cur- rent test |
||||||||||
Main |
Aux |
||||||||||||||||
NO |
NC |
NO |
NC |
||||||||||||||
01 |
X1,X2 |
28 |
dc |
55 |
29 |
0.6 |
18 |
21 |
22.5 |
1.5 |
7 |
60 |
25 |
2.5 |
n/a |
n/a |
n/a |
02 |
X1,X2 |
28 |
dc |
55 |
29 |
0.6 |
18 |
21 |
22.5 |
1.5 |
7 |
60 |
25 |
2.5 |
n/a |
4.5 |
4.5 |
A3 |
X1,X2 |
115 |
400/50/60 6/ |
120 |
0.25 |
90 |
100 |
104 |
10 |
40 |
65 |
80 |
5 |
n/a |
n/a |
n/a |
|
A4 |
X1,X2 |
115 |
400/50/60 6/ |
120 |
0.25 |
90 |
100 |
104 |
10 |
40 |
65 |
115 |
5 |
n/a |
7 |
7 |
1/ CAUTION: Use of any coil voltage less than rated coil voltage will compromise the operation of the relay.
2/ Over the temperature range.
3/ At 50 and 60 Hz, chattering may occur at or near dropout voltage when voltage is slowly decreased.
4/ With rated coil voltage.
5/ From rated coil voltage.
6/ Coils will operate at either 50, 60, or 400 Hz; however, ambient temperature must not exceed +71°C.
5