MS24168T
REQUIREMENTS:
Dimensions and configurations: See figure 1.
Part or Identifying Numbers (PIN's) and general characteristics: See table I. Contact data:
Load ratings: See table II.
Maximum contact drop, initial: 0.150 V. After life test: 0.175 V.
Overload current (NO): 800 amperes. 1/ Rupture current (NO): 1,000 amperes. 1/
Coil data: See table III. Duty rating: Continuous.
RFI specification: MIL-STD-461 (applicable to coil circuits of ac operated relays). Electrical data:
Minimum insulation resistance: Initial: 100 megohms.
After life or environmental test: 50 megohms. Dielectric strength: 2/
Sea level, 2-5 seconds:
Initial |
After life tests |
|||
28 V dc |
115 V ac |
28 V dc |
115 V ac |
|
Coil to case: |
1,250 V rms |
1,500 V rms |
1,000 V rms |
1,125 V rms |
Aux. contacts: |
1,250 V rms |
1,500 V rms |
1,000 V rms |
1,125 V rms |
All other points: |
1,250 V rms |
1,800 V rms |
1,000 V rms |
1,350 V rms |
Altitude, 1 minute: 3/
28 V dc |
115 V ac |
|
Coil to case: |
500 V rms |
500 V rms |
Aux. contacts: |
500 V rms |
500 V rms |
All other points: |
700 V rms |
700 V rms |
1/ For 50/60 Hz, overload and rupture currents (NO) are 200 amperes.
2/ For A3 and A4, coil terminals X1 and X2 shall be shorted together for all dielectric testing.