MIL-DTL-83726/27L
TABLE IV. Field intensity levels.
Frequency |
RS103 (volts/meter) |
14 kHz to 200 MHz 200 MHz to 450 MHz 450 MHz to 1 GHz 1 GHz to 12 GHz |
20 65 20 100 |
Environmental data:
Temperature range (operating): -70°C to +85°C. +171°C nonoperating, 10 minutes. +200°C, nonoperating, 1 minute.
Altitude: 80,000 feet. Shock:
G level: 50 g's.
Duration: 10 milliseconds.
Contact opening: 10 microseconds, maximum. Contact closing: 1 microsecond, maximum.
Vibration (sinusoidal): G level: 30 g's.
Frequency range: 10 Hz to 3,000 Hz.
Vibration (random): Applicable in accordance with MIL-STD-202, method 214, test condition 1B.
Power specter density: 0.4 g2/Hz. Frequency range: 50 Hz to 2,000 Hz. Duration: 15 minutes each plane.
Vibration scan:
Frequency range: 5 Hz to 2,000 Hz.
Intensity: 0.01 inch double amplitude or ±2 g's (whichever is less). Acceleration: 15 g's.
Seal: Applicable to nonhermetically-sealed relays and hermetically-sealed (potted) relays.