MIL-DTL-83726/27L
REQUIREMENTS: Operating data:
Configuration: SPDT.
Life/load ratings: See table I. Timing action: See table II.
TABLE I. Life/load ratings (relay case grounded).
Type of load |
Life (cycles) |
Amperes 28 V dc |
Resistive Inductive Lamp Mechanical life (reduced current) Intermediate current |
100,000 50,000 100,000 400,000 100,000 |
2.0 0.5 0.2 0.5 0.50 |
Contact drop:
Initial: 0.150 volt maximum.
After life tests: 0.175 volt maximum. Minimum current: 0.050 ampere. Contact bounce: See table II.
Overload:
DC: 8 amperes minimum. AC: Not applicable.
Rupture:
DC: 10 amperes minimum. AC: Not applicable.
Input data:
Duty ratings: Continuous. Input voltage:
Maximum: See table II.
Rated: See table II.