MIL-R-83726/23D
Minimum voltage: 20 V dc.
Minimum voltage (high-temperature test): 20 V dc. Minimum voltage (continuous current test): 20 V dc.
Peak current (-55°C to +100°C): 2.5 amperes for 100 milliseconds (maximum). Steady-state dc current: 0.060 ampere (maximum).
Release time delay: See table I.
Recycle time: 1/
Maximum operate time: See table I. Electrical data:
Insulation resistance at 500 V dc: 2/ Initial: 1,000 megohms (minimum).
After life or environmental tests: 500 megohms (minimum).
Dielectric withstanding voltage (sea level): Input (X1 - X2) 2/
All other points.
Dielectric withstanding voltage (altitude) (80,000 feet): 2/
Input (X1 - X2): 350 V rms. 2/
All other points: 350 V rms.
Transients: In accordance with MIL-STD-704 for 28 volts dc system (figure 11).
1/ Recycle time is the same as operate time in table I. It is defined as the minimum time that operate voltage must be applied to the input terminals to assure that a new release timing cycle can be completed within the specified timing tolerance.
2/ Input terminals X1 and X2 shall be connected together during this test.