MIL-R-39016/34F
REQUIREMENTS: CONTACT DATA:
Load ratings:
High level (relay case grounded):
Resistive: 1.0 ampere maximum at 28 V dc maximum.
Inductive: 0.2 ampere maximum at 28 V dc maximum with 200 millihenries minimum. Lamp: 0.100 ampere at 28 V dc.
Low level: 10 µA to 50 µA at 10 mV to 50 mV dc or peak ac. Intermediate current: Applicable.
Contact resistance or voltage drop: 1/
Initial: 0.050 ohm maximum. High level:
During life: Not more than 5 percent of open circuit voltage. After life: 0.100 ohm maximum.
Low level:
During life: 33 ohms maximum. After life: 0.150 ohm maximum.
Intermediate current:
During intermediate current: 1 ohm maximum. After intermediate current: 0.100 ohm maximum.
Contact bounce: 2.0 milliseconds (ms) maximum.
Contact stabilization time: 2.5 milliseconds (ms) maximum. Overload (high level only): Two times rated current.
COIL DATA: See table I.
Operate time: 4 ms maximum over temperature range with rated coil voltage. Release time: 4 ms maximum over temperature range from rated coil voltage.
1/ For tab mount only, add 0.025 ohm to the contact resistance values specified.