TABLE I. Dash numbers and characteristics.
Dash numbers |
Mount |
Coil voltage 41 (V dc) |
At +25qC |
Over temperature range |
|||||||||
Wire lead 1.50 ±.020 |
Wire lead (solder pin-SP) .187 ±.020 |
Wire lead (solder pin-SP) .25 ±.02 |
Pin (plug in) .187 ±.020 21 31 |
Coil resistance ohms ±10% |
Specified pickup value (voltage) (V dc) |
Specified hold value (voltage) (V dc) |
Specified dropout value (voltage) (V dc) |
Specified pickup value (voltage) (V dc) |
Specified hold value (voltage) (V dc) |
Specified dropout value (voltage) V dc |
|||
Rated |
Max |
||||||||||||
-001 -004 -007 |
-002 -005 -008 |
-003 -006 -009 |
-010 -011 -012 -013 -014 -015 |
Bracket No mount Tab mount Bracket No mount Tab mount Bracket No mount Tab mount No mount No mount No mount Flange mount Flange mount Flange mount |
6.0 6.0 6.0 12 12 12 26.5 26.5 26.5 6.0 12 26.5 6.0 12 26.5 |
8.0 8.0 8.0 16 16 16 32 32 32 8.0 16 32 8.0 16 32 |
90 90 90 310 310 310 1,500 1,500 1,500 90 310 1,500 90 310 1,500 |
3.0 3.0 3.0 6.0 6.0 6.0 13.5 13.5 13.5 3.0 6.0 13.5 3.0 6.0 13.5 |
1.5 1.5 1.5 3.0 3.0 3.0 10 10 10 1.5 3.0 10 1.5 3.0 10 |
0.3 0.3 0.3 0.6 0.6 0.6 1.5 1.5 1.5 0.3 0.6 1.5 0.3 0.6 1.5 |
4.0 4.0 4.0 8.0 8.0 8.0 18 18 18 4.0 8.0 18 4.0 8.0 18 |
2.0 2.0 2.0 4.0 4.0 4.0 14 14 14 2.0 4.0 14 2.0 4.0 14 |
0.2 0.2 0.2 0.4 0.4 0.4 1.0 1.0 1.0 0.2 0.4 1.0 0.2 0.4 1.0 |
11 Each relay possesses high level and low level capabilities. However, relays previously tested or used above 10 mA resistive at 6 V dc or peak ac open circuit are not recommended for subsequent use in low level applications.
21 Pins (plug-in) are gold plated leads.
31 Socket plug-in relays are not to be used in Air Force airborne applications.
41 CAUTION: The use of any coil voltage less than rated coil voltage will compromise the operation of the relay.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business