MIL-PRF-83726/35D
Marking: See MIL-PRF-83726. In addition, relays shall be marked with the ESDS identifier as
specified in MIL-STD-1285.
Part or Identifying Number (PIN): Consists of the prefix M83726/35-, a four digit dash number (time
delay expressed in milliseconds), and a suffix letter (P for plug-in, S for solder lug):
M
83726/35-
1001
P
Military designation
Specification sheet number
The first three digits are significant; the fourth is the
number of zeros to follow the first three digits. The time
is expressed in milliseconds and converted to seconds.
(See examples.)
Suffix letter. (Any relay numbered prior to the date of this specification shall
be considered interchangeable with same mounting type, store and issue.)
Examples:
M83726/35-1001P 1 second time delay, plug-in.
M83726/35-9002S 90 second time delay, solder lug
NOTE: Time delay relays within the 0.1 second to 600 second delay range are available.
Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where
changes from the previous issue were made. This was done as a convenience only and the Government assumes
no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the
requirements of this document based on the entire content irrespective of the marginal notations and relationship to
the last previous issue.
Referenced documents. In addition to MIL-PRF-83726, this document references the following: