MIL-PRF-83536/23A
TABLE III. Dash numbers and characteristics. 1/
Coil data
Over
Dash number 2/
At 25°C
temperature
Maximum
range
pickup voltage
Mount
Coil voltage
Continuous
Specified
High
Specified
Coil
current
latch/
temper-
Solder
(V dc) 3/
Solder
Socket
resistance
latch/
pin
hook
pin
test
reset
ature
reset
(ohms)
voltage
test
voltage
minimum
(V dc ) 4/
(V dc ) 4/
Rated
Max
No
001
002
003
mount
6
7.3
33
3.2
4.5
5.0
5.7
004
005
006
RVFM
6
7.3
33
3.2
4.5
5.0
5.7
007
008
---
HFM
6
7.3
33
3.2
4.5
5.0
5.7
No
009
010
011
mount
12
14.5
130
6.5
9.0
9.9
11.25
012
013
014
RVFM
12
14.5
130
6.5
9.0
9.9
11.25
015
016
---
HFM
12
14.5
130
6.5
9.0
9.9
11.25
No
540
13.5
18.0
19.8
22.5
017
018
019
mount
28
29 5/
540
13.5
18.0
19.8
22.5
020
021
022
RVFM
28
29 5/
540
13.5
18.0
19.8
22.5
023
024
---
HFM
28
29 5/
No
025
026
027
mount
48
50
1,630
24.0
36.0
38.0
42.0
028
029
030
RVFM
48
50
1,630
24.0
36.0
38.0
42.0
031
032
---
HFM
48
50
1,630
24.0
36.0
38.0
42.0
1/ Each relay possesses high level and low level capabilities. However, relays previously tested or used above
10 mA resistive at 6 V dc maximum or peak ac open circuits are not recommended for subsequent use in low
level applications.
2/ The suffix letter L, M, P, or R to designate the applicable failure rate level shall be added to the applicable listed
dash number. Failure rate level (percent per 10,000 cycles): L, 3.0; M, 1.0; P, 0.1; R, 0.01.
Example: 001L, 002R.
3/ CAUTION: The use of any coil voltages less than the rated coil voltage will compromise the operation of the
relay.
4/ Pickup voltages as shown is for test purposes only and is not to be used for design criteria.
5/ When maximum ambient temperature does not exceed +85°C, the maximum coil voltage shall be 32 V dc.
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business