MIL-PRF-83536/23A
Bend: Applicable.
Twist: Applicable.
Socket pin terminals:
Pull force:
For .040 diameter terminals: 5 pounds ±0.5 pound.
For .062 diameter terminals: 10 pounds ±0.5 pound.
Bend: Applicable.
Twist: Not applicable.
Terminal solderability: Applicable to solder pin and solder hook terminals only.
Seal: Hermetic.
Marking: Applicable.
Part or Identifying Number (PIN): M83536/23 (dash number from table III and suffix letter designating failure rate
level).
Qualification inspection:
Qualification inspection and sample size: See table IV.
TABLE IV. Qualification inspection and sample size. 1/
Single submission
Group submission
18 units plus 1 open unit
M83536/23-022
18 units plus 1 open unit
for level L at C = 0 2/
for level L at C = 0 2/
M83536/23-022
33 units plus 1 open unit for level
33 units plus 1 open unit
M at C = 0 2/
for level M at C = 0 2/
Qualification inspection
M83536/23-022
Qualification inspection as
as applicable
applicable
M83536/23-018
2 units, qualification inspection
M83536/23-023
table, Q2, shock, vibration,
acceleration, terminal strength,
and seal
M83536/23-002
2 units, qualification inspection
M83536/23-014
table, Q1
M83536/23-031
1/ For retention of qualification or extension of qualification to lower failure rate levels, all life
test data accumulated on MIL-PRF-83536/24 may be used in addition to MIL-PRF-
83536/23 data. Prior to performance of retention of qualification testing, the relay
manufacturer shall preselect the sampling plan.
2/ The number of units required for qualification testing shall be increased as required in
Q5, table II of MIL-PRF-83536, if the contractor elects to test the number of units
permitting one or more failures. Prior to performance of qualification testing, the relay
manufacturer shall preselect the sampling plan.
10
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business