TABLE I. Dash number and operating characteristics.
Coil data
Time milliseconds-maximum
Dash
Type
Coil
Nominal
Maximum
Bounce
no.
Volts
Freq
Res
Volts
Ampere
Main
Auxiliary
1/
Inrush
Steady
NO
NC
NO
NC
state
-001
1
X1, X2
28
DC
-
29
1.25
.25
2
2
-
-
-002
1
X1, X2
28
DC
-
29
1.25
.25
17
20
21.5
7.0
1.5
25
25
2
2
2
2
-003
1
X1, X2
115
400
-
124
.71
.1
85
95
100
40
10
25
55
2
2
-
-
-004
1
X1, X2
115
400
-
124
.71
.1
85
95
100
40
10
25
55
2
2
2
2
1/ Over the temperature range
2/ With nominal coil voltage
3/ From nominal coil voltage
TABLE II. Rated contact load (amperes per pole) (case grounded).
28 V dc 1/
115 V ac, 1 phase 1/
115/200 V ac, 3 phase 1/
Type of
Life
load
operating
Main
cycles
NO
NC
NO
NC
400 Hz
60 Hz
400 Hz
60 Hz
400 Hz
60 Hz
400 Hz
60 Hz
3
x10
Resistive
100
-
-
3
3
60
-
3
-
60
-
-
-
Inductive
100
-
-
1.5
1.5
60
-
1.5
-
60
-
-
-
Motor
50
-
-
-
-
40
-
-
-
40
-
-
-
Lamp
-
-
.5
.5
-
.5
-
-
-
-
Transfer
-
-
-
-
-
-
-
load 2/
Mechanical
200
-
-
.75
.75
15
-
.75
-
15
-
-
-
life reduced
current
Mixed
50
-
-
Per spec
4
-
-
-
4
-
-
-
loads 3/
1/ Absence of value indicates relay is not rated for that application.
2/ Transfer load indicates relay suitable for transfer between unsynchronized ac power supplies at rating.
3/ Mixed loads to be conducted at +71C. Number of mixed loads cycles following continuous current test - 5000.
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business