TABLE I. Mounting, termination, and operating characteristics.
Coil data
Time (milliseconds-maximum)
Nominal
Maximum
Max pickup voltage 1/
Contact bounce
Main
Aux
Mounting
Terminals
Coil
Dash
Hold
Drop
Oper Re-
Cont
Res
High
Volts
Amp
10%
term-
no.
-ate lease NO
current
temp
NC
NO
NC
inal
test
test
X1, X2
-001
DC
28
DC
---
29
0.25
18
19.5
22.5
---
4.0
4.0
Solder hook
4 Studs
-002
AC
115
400
---
122
.055
96
100
108
40
5.0
25
50
2.0
---
4.0
4.0
Solder hook
4 Studs
-003
AC
115
50/60
---
122
.06
96
100
108
40
5.0
25
50
2.0
---
4.0
4.0
Solder hook
4 Studs
-004
DC 5/
28
DC
160
29
0.25
18
19.5
22.5
7.0
1.5
20
10
2.0
---
4.0
4.0
Solder hook
4 Studs
1/
CAUTION: Use of any coil voltage less than nominal coil voltage will compromise the operation of the relay.
2/
Over the temperature range.
3/
With nominal coil voltage.
4/
From nominal coil voltage.
5/
Suppressed dc coil: Back EMF 42 volts maximum.
TABLE II. Rated contact load (amperes per pole) case grounded.
Life
See
Type of load
operating
approp-
115/200 V ac, 3 phase 1/
115 V ac, 1 phase
28 V dc
cycles x
3
riate
10
footnote
Main
Aux
Main
Aux
Main
Aux
400 Hz
60 HZ
400 Hz
60 Hz
400 Hz
50/60
NO
NC
NO
NC
400 Hz
50/60
Hz
Hz
Resistive
50
25
---
2
2
25
25
2
---
25
25
---
---
Inductive
10
15
---
1
1
25
25
1
1
25
25
---
---
Motor
50
20
---
---
---
20
12
---
---
20
12
---
---
Lamp
50
10
---
.5
.5
10
10
.5
---
10
10
---
---
Transfer load
---
---
---
---
---
---
---
---
---
---
---
---
Mechanical life
100
6.3
---
.5
.5
6.3
6.3
.5
---
6.3
6.3
---
---
reduced current
Mixed loads
Applicable per specification
1/ Absence of value indicates relay is not rated for 3 phase applications.
2/ .7 pF, inductive.
3/ Transfer load indicates relay suitable for transfer between unsynchronized ac power supplies at rating indicated.