MIL-PRF-6106/41C
REQUIREMENTS:
Coil data:
Coil data: See table I.
Duty rating: Continuous.
Operational data:
Rated contact load: See table II.
Operate time: See table I.
Release time: See table I.
Maximum induced transient voltage (when specified): 42 V.
Physical:
Dimensions and configurations: See figure 1.
Weight (maximum): 0.44 pound (200 grams).
Strength of terminals and mounting studs: Applicable.
Terminal solderability:
Finish: Flat black.
ENVIRONMENTAL CHARACTERISTICS:
Temperature rating: -70C to +125C.
Maximum altitude rating: 80,000 feet.
Shock, g-level: 50 g.
Duration: 11 ms.
Maximum duration contact opening: 2 ms.
Vibration - sinusoidal:
Operating:
G-level: 10 g.
Frequency range: 5 to 1,500 Hz.
Nonoperating:
G-level: 15 g.
Frequency range: 20 to 2,000 Hz.
Acceleration: 10 g.