MIL-PRF-6106/20D
TABLE II. Rated contact load (amperes per pole) case grounded.
Life
28 V dc
115 V ac,1 phase
115/200 V ac, 3 phase 1/
See
opera-
Main
Aux
Main
Aux
Main
Aux
appro-
Type of
ing
priate
load
400
400
cycles
NO
NC
NO
NC
60 Hz
400 Hz
60 Hz
400 Hz
60 Hz
60 Hz
notes
Hz
Hz
3
X 10
Resistive
50
25
25
25
2/
Inductive
10
12
12
Inductive
20
15
Motor
50
10
10
10
Lamp
50
5
5
5
Transfer,
3/
load
Mechanical
life reduced
6
200
6
6
current
Intermediate
current
APPLICABLE (See MIL-PRF-6106)
Mixed loads
APPLICABLE (See MIL-PRF-6106)
1/ Absence of value indicates relay is not rated for 3 phase application.
2/ For full rated load maximum temperature and altitude use no. 12 wire or larger. Solder hook relays to be
mounted to limit mounting bracket temperature to 135°C.
3/ Transfer load indicates relay suitable for transfer between unsynchronized ac power supplies at rating indicated.
6