MIL-PRF-6106/20D
Maximum contact drop, initial: 0.150 volt.
After life test: 0.175 volt.
Overload current: 50 amperes dc, 80 amperes ac, 400 Hz.
Rupture current: 60 amperes dc, 100 amperes ac, 400 Hz.
Duty rating: Continuous.
Part or Identifying Number (PIN): M6106/20- (plus dash number from table I). Example: M6106/20-001.
Qualification by similarity: See MIL-PRF-6106.
Suspension of inspection. Group B and Group C inspections may be suspended at the discretion of the qualifying
activity.
TABLE I. Dash numbers and characteristics.
Time-milliseconds
Coil data
maximum 1/
Max pick-up
Bounce
Nominal
Max
Term-
Mount-
voltage
inal
ing
Cont
type
style
Dash
Coil
Ope-
Re-
Main
Volts
Res
Volts
Amp
Nom-
High
cur-
numbers
rate
set
Ω
(V dc)
inal
temp
rent
NO
NC
±10%
2/
3/
test
test
X1-X2
Solder
-001
28
600
29
.050
18
19.8
22.5
10
10
1.0
1.0
RVFM
Y1-Y2
hook
X1-X2
-002
28
600
29
.050
18
19.8
22.5
10
10
1.0
1.0
Plug-in
RVFM
Y1-Y2
X1-X2
Solder
-003
28
600
29
.050
18
19.8
22.5
10
10
1.0
1.0
HFM
Y1-Y2
hook
1/ With nominal coil voltage.
2/ Caution: Use of any coil voltage less than nominal coil voltage will compromise the operation of the relay.
3/ Over temperature range.