MIL-PRF-6106/12F
TABLE I. Operating characteristics.
1/ Caution: Use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2/ Over the temperature range.
3/ With rated coil voltage.
TABLE II. Rated contact load (amperes per pole) (case grounded). 1/ 2/ 3/
28 V dc
115 V ac, 1 phase
115/200 V ac, 3 phase 1/
Life
Main
Aux
Main
Aux
Main
Aux
Type of load
operating
400
60
400
60
400
60
400
60
cycles
NO
NC
NO
NC
x103
Hz
Hz
Hz
Hz
Hz
Hz
Hz 2/
Hz
4/
50
25
2
2
25
2
25
Resistive
Inductive
10
12
Inductive
10
1
1
15
1
15
Motor
50
10
10
10
Lamp
50
5
.5
.5
5
.5
5
5/
Transfer load
Mechanical
200
6
6
6
life reduced
current
Intermediate
Applicable in accordance with MIL-PRF-6106 (main contacts only)
current
Mixed loads
Applicable in accordance with MIL-PRF-6106
1/
Absence of value indicates relay is not rated for 3 phase application.
2/
Single phase load shall be run during the 3 phase test on auxiliary contacts.
3/
Absence of value indicates parameter is not applicable to this specification sheet.
4/
For full rated load at maximum temperature and altitude, use no. 12 wire or larger. Solder hook relays shall
be mounted to limit mounting bracket temperature to +135°C.
5/ Transfer load indicates relay is suitable for transfer between unsynchronized ac power supplies at the