TABLE I. Dash number and operating characteristics.
Coil data
Time milliseconds-maximum
Type
Dash no.
Bounce
Coil
Nominal
Maximum
Main
Auxiliary
Volts
Freq
Res
Volts
Ampere
Inrush
Steady
NO NC
NO
NC
state
-001
1
X1, X2
28
DC
-
29
1.25
.25
17
20
21.5
7.0
1.5
25
25
2
-
-
-
-002
1
X1, X2
28
DC
-
29
1.25
.25
17
20
21.5
7.0
1.5
25
25
2
-
2
2
-003
1
X1, X2
115
400
-
124
.71
.1
85
95
100
40
10
25
55
2
-
-
-
1
X1, X2
115
400
-
124
.71
.1
85
95
100
40
10
25
55
2
-
2
2
-005 4/
1
X1, X2
28
DC
-
29
1.25
.25
17
20
21.5
7.0
1.5
25
25
-
-
-
-
1/ Over the temperature range
2/ With nominal coil voltage
3/ From nominal coil voltage
4/ -005 is same as -001 except for transient suppressed coil.
TABLE II. Rated contact load (amperes per pole) (case grounded).
28 V dc 1/
115 V ac, 1 phase 1/
115/200 V ac, 3 phase 1/
Life
Type of
operating
Main
Auxiliary
Main
Auxiliary
Main
Auxiliary
load
cycles
NO
NC
NO
NC
400 Hz
60 Hz
400 Hz
60 Hz
400 Hz
60 Hz
400 Hz
60 Hz
3
x10
Resistive
100
-
-
3
3
60
-
3
-
60
-
-
-
Inductive
100
-
-
1.5
1.5
60
-
1.5
-
60
-
-
-
Motor
50
-
-
-
-
40
-
-
-
40
-
-
-
Lamp
-
-
.5
.5
-
.5
-
-
-
-
Transfer
-
-
-
-
-
-
-
load 2/
200
-
-
.75
.75
15
-
.75
-
15
-
-
-
life reduced
50
-
-
Per spec
4
-
-
-
4
-
-
-
loads 3/
1/ Absence of value indicates relay is not rated for that application.
2/ Transfer load indicates relay suitable for transfer between unsynchronized ac power supplies at rating.
3/ Mixed loads to be conducted at +71C. Number of mixed loads cycles following continuous current test - 5000.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business