MIL-PRF-39016/55B
REQUIREMENTS:
Cleaning and small particle inspection: Applicable.
CONTACT DATA:
Load ratings:
High level (relay case grounded):
Resistive: 2 amperes at 28 V dc, 0.1 ampere at 115 V ac, (60 and 400 Hz).
Inductive: 0.5 ampere at 28 V dc with 0.200 henry inductance.
Lamp: 0.160 ampere at 28 V dc.
Low level: 10 µA to 50 µA at 10 mV to 50 mV dc or peak ac.
Intermediate current: Applicable.
Contact resistance or voltage drop:
High level:
Before life: 0.050 ohm maximum.
During life: Not more than 5 percent of open circuit voltage.
After life: 0.100 ohm maximum.
Low level:
Before life: 0.050 ohm maximum.
During life: 33 ohms maximum.
After life: 0.150 ohm maximum.
Intermediate current:
Before: 0.050 ohm maximum.
During: 1 ohm maximum.
After: 0.100 ohm maximum.
Contact bounce: 2.0 milliseconds (ms) maximum (applicable to failure rate level L).
Contact stabilization time: 2.0 ms maximum (applicable to failure rate levels M, P, and R).
Overload (high level only): Two times rated current.