TABLE I. Dash numbers and characteristics. 1/
At 25°
Over temperature range
Coil
Speci-
Speci-
Speci-
Speci-
Speci-
Max coil
Min coil
Speci-
Coil
Dash
voltage
fied
fied
fied
fied
fied
current
current
fied
resis-
Leads
number
V dc 3/
Mount
dropout
hold
pickup
dropout
hold
(mA)
(mA)
pickup
tance
2/
value
value
value
value
value
value
(Ref
(volt-
(volt-
(volt-
(volt-
(volt-
(volt-
only)
Rated
Max
age)
age)
age)
age)
age)
age)
Ohms
±10%
(V dc)
(V dc)
(V dc)
(V dc)
(V dc)
(V dc)
Lug
Flange
001
6
7
28
218.25
162.34
3.7
2.3
0.5
4.8
2.9
0.4
Wire (SP)
No mount
002
Wire (SP)
Flange
015
Wire (PI)
Flange
016
Lug
Flange
003
9
11
73
129.38
99.63
5.2
3.2
0.6
6.6
4.1
0.5
Wire (SP)
No mount
004
Wire (SP)
Flange
017
Wire (PI)
Flange
018
Lug
Flange
005
12
14
115
111.11
86.96
6.4
3.9
0.8
8.6
5.0
0.6
Wire (SP)
No mount
006
Wire (SP)
Flange
019
Wire (PI)
Flange
020
Lug
Flange
007
18
22
280
69.44
55.19
9.4
5.7
1.0
12.2
7.4
0,7
Wire (SP)
No mount
008
Wire (SP)
Flange
021
Wire (PI)
Flange
022
Lug
Flange
009
22
27
430
55.56
44.40
11;3
6.7
1.2
15.0
8.7
0.8
Wire (SP)
No mount
010
Wire (SP)
Flange
023
Wire (PI)
Flange
024
Lug
Flange
011
26.5
35
720
40.12
32.20
14.5
8.8
1.7
19.0
11.5
1.1
Wire (SP)
No mount
012
Wire (SP)
Flange
025
Wire (PI)
Flange
026
Lug
Flange
013
36
42
1,040
37.93
30.59
18.2
11.1
2.1
23.8
15.0
1.3
Wire (SP)
No mount
014
Wire (SP)
Flange
027
Wire (PI)
Flange
028
1/ Each relay possesses high level and low level capabilities. However, relays previously tested or used above 10 mA resistive at 6 V dc
maximum or peak ac open circuit are not recommended for subsequent use in low level applications.
2/ The suffix letter L, M, P, or R to designate the applicable failure rate level shall be added to the applicable listed dash number. Failure rate
level (percent per 10,000 cycles): L, 3.0; M, 1.0; P, 0.1; R, 0.01. Example, 001L - - - - - 003R.
3/ CAUTION: The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
4/ Coil resistance not directly measurable at relay terminals. When rated voltage is applied to the coil terminals, the coil circuit current shall be
within the limits shown. Measure at 25°C at nominal voltage for 5 seconds maximum.